翻訳と辞書
Words near each other
・ IMBER
・ Imber
・ Imber (disambiguation)
・ Imber friendly fire incident
・ Imber tropicus
・ Imber's petrel
・ Imberdown (electoral division)
・ Imberhorne School
・ Imberhorne Viaduct
・ Imbersago
・ Imbert
・ Imbert de Batarnay
・ Imbert Jebbink
・ Imbert Prize
・ Imbert, Puerto Plata
Imbert-Fick law
・ Imbert-Terry baronets
・ Imbert–Fedorov effect
・ Imbestigador
・ Imbi
・ Imbi Hoop
・ Imbi Monorail station
・ Imbi Paju
・ Imbia Sylvester Itoe
・ Imbiah Lookout
・ Imbibe
・ Imbibition
・ Imbil Railway Bridge
・ Imbil, Queensland
・ Imbira


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Imbert-Fick law : ウィキペディア英語版
Imbert-Fick law

The Imbert-Fick "law" was invented by Hans Goldmann (1899–1991) to give his newly marketed tonometer (with the help of the Haag-Streit Company) a quasi-scientific basis; it is mentioned in the ophthalmic and optometric literature, but not in any books of physics. According to Goldmann,〔Goldmann H. Applanation Tonometry. Transactions Second Glaucoma Conference. New York, Josiah Macy, Jr Foundation. 1957.〕 "The law states that the pressure in a sphere filled with liquid and surrounded by an infinitely thin membrane is measured by the counterpressure which just flattens the membrane." "The law presupposes that the membrane is without thickness and without rigidity...practically without any extensibility."
The problem is that a sphere formed by such a membrane and filled with incompressible liquid (water) cannot be indented or applanated even when the pressure inside is zero, because a sphere contains the maximum volume with the minimum surface area.〔Koster W. Beitraege zur Tonometrie und Mnometrie des Auges. Graefe's Arch.Ophthalmol. 1895; 41: 113-158.〕〔Markiewitz HH. The so-called Imbert-Fick Law. AMA Arch.Ophthalmol. 1960; 64: 189/159.〕 Any deformation necessarily increases surface area, which is impossible if the membrane is inelastic, such as aluminum foil.
The actual physical basis of tonometry is Newton's third law of motion: "If you press a stone eyeball with your finger, the finger is also pressed by the stone eyeball."
The law is this: Intraocular pressure = Contact force/Area of contact
The law assumes that the cornea is infinitely thin, perfectly elastic, and perfectly flexible.〔Whitacre, MM, Stein, R. (1993) Sources of error with use of Goldmann-type tonometers Surv Ophthalmol 38,1-30〕 None of these assumptions are true. The cornea is a membrane that has thickness and offers resistance when pressed.〔Anders Eklund, Per Hallberg, Christina Lindén, and Olof A. Lindahl. (2003) An Applanation Resonator Sensor for Measuring Intraocular Pressure Using Combined Continuous Force and Area Measurement〕 Therefore, in Goldmann tonometry, readings are normally taken when an area of 3.06mm diameter has been flattened. At this point the opposing forces of corneal rigidity and the tear film are roughly approximate in a normal cornea and cancel each other out allowing the pressure in the eye to be inferred from the force applied.〔The Glaucoma Book, Paul N. Schacknow, John R. Samples, p.79〕
==Notes==


抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「Imbert-Fick law」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.